In modern electrical systems, uninterrupted power is a necessity. Industries, commercial facilities, hospitals, data centers, and even large residential complexes depend on reliable power switching and precise load control to protect equipment and control costs. This is where Automatic Changeover with Current Limiter (ACCL) becomes a game-changer.
The Elmeasure M300 is one such advanced energy monitoring and control device that integrates ACCL functionality to intelligently manage power sources while limiting load demand. In this blog, we’ll break down what ACCL really means, how it works inside the Elmeasure M300, why it matters for real-world applications, and how it helps reduce energy risks, penalties, and downtime.
Why Power Changeover Needs to Be Smarter Today
Traditional power changeover systems are designed mainly to switch between two sources—typically utility supply and a generator. While this solves basic continuity issues, it doesn’t address a critical problem: uncontrolled current draw during changeover.
When loads are transferred without limitation:
- Generators may overload
- Equipment can trip or fail
- Demand penalties may rise
- System stability suffers
This is exactly where Automatic Changeover with Current Limiter (ACCL) adds intelligence to the system—not just switching power, but managing how much power flows.
What Is Automatic Changeover with Current Limiter (ACCL)?
Automatic Changeover with Current Limiter (ACCL) is an advanced control logic that performs two functions simultaneously:
- Automatically switches between power sources (such as mains and DG)
- Limits the load current during and after changeover to a predefined safe value
Unlike conventional automatic changeover switches that blindly transfer the entire load, ACCL ensures that the connected load never exceeds the permissible current threshold—especially important when operating on generator or limited-capacity sources.
In simple terms, ACCL answers two critical questions:
- When should the power source change?
- How much load should be allowed after changeover?
Introducing Elmeasure M300
The Elmeasure M300 is a multifunction energy meter built for both monitoring and control applications. It is widely used in industrial and commercial power systems where accurate measurement, intelligent switching, and effective load management are essential.
Key capabilities include:
- High-accuracy electrical parameter measurement
- Programmable digital inputs and outputs
- Advanced logic for automation and protection
- Built-in support for Automatic Changeover with Current Limiter (ACCL) functionality
With integrated ACCL support, the Elmeasure M300 does more than measure energy — it actively manages loads and enables intelligent source changeover. It functions as a smart decision-making device within your electrical system.
Enquire Now – Available at BSPL
Looking to integrate Elmeasure M300 with ACCL in your project?
Get genuine products, technical support, and competitive pricing from BSPL.
📞 Contact our team today for specifications and pricing
📩 Request a quote now
Connect with BSPL and upgrade your power management system with Elmeasure M300.
How ACCL Works in Elmeasure M300
To understand the value of ACCL in the Elmeasure M300, let’s walk through its operation step by step.
1. Continuous Monitoring of Electrical Parameters
The Elmeasure M300 constantly monitors:
- Current on each phase
- Voltage levels
- Load demand
- Power availability
This real-time data forms the basis for all ACCL decisions.
2. Detection of Power Source Failure or Change
When the M300 detects:
- Mains failure
- Voltage outside acceptable limits
- Frequency deviation
It initiates the automatic changeover process to the alternate power source, such as a DG set.
3. Controlled Load Transfer Using Current Limiter
Here’s where ACCL makes the real difference.
Instead of allowing the full load to transfer instantly, Automatic Changeover with Current Limiter (ACCL):
- Restricts current to a preset limit
- Prevents sudden inrush or overload
- Allows gradual or prioritized load pickup
This ensures the generator or alternate source operates safely within its rated capacity.
4. Intelligent Load Restoration
As system conditions stabilize:
- Additional loads may be allowed
- Non-essential loads can remain restricted
- Priority loads remain protected
The Elmeasure M300 continuously evaluates conditions and adjusts output accordingly.
Why ACCL Is Critical in Generator-Based Systems
Generators are particularly vulnerable during changeover. Unlike utility power, they:
- Have limited current capacity
- Are sensitive to sudden load changes
- Can stall or trip under overload
By using ACCL in Elmeasure M300, facilities gain:
- Protection against generator overload
- Stable voltage and frequency
- Longer generator life
- Reduced fuel consumption
This makes ACCL especially valuable in hospitals, manufacturing plants, malls, and IT facilities.
Key Benefits of Automatic Changeover with Current Limiter (ACCL)
1. Prevents Overloading
The most direct benefit of ACCL is current limitation. It ensures that connected loads never exceed safe operating limits, especially during emergencies.
2. Improves System Reliability
By avoiding trips, voltage dips, and sudden failures, ACCL improves overall system uptime and reliability.
3. Protects Electrical Equipment
Sensitive equipment such as VFDs, PLCs, servers, and medical devices are protected from power disturbances during source transitions.
4. Optimizes Energy Usage
ACCL helps control demand, which can reduce:
- Maximum demand charges
- Penalties from utilities
- Unnecessary generator runtime
5. Enables Smarter Load Management
Using Elmeasure M300 logic and outputs, ACCL can be integrated with:
- Load shedding schemes
- Priority-based distribution
- Automation systems
Typical Applications of ACCL with Elmeasure M300
The combination of Elmeasure M300 and ACCL is widely used across sectors:
Industrial Plants
- Protects motors and heavy machinery
- Prevents generator tripping
- Supports phased load restoration
Commercial Buildings
- Controls HVAC, lighting, and elevators
- Reduces peak demand stress
- Improves occupant safety during outages
Hospitals and Healthcare
- Ensures uninterrupted supply to critical equipment
- Controls non-essential loads automatically
- Enhances patient safety
Data Centers
- Maintains power quality during transitions
- Protects servers from overload
- Ensures smooth DG operation
ACCL vs Conventional Automatic Changeover
| Feature | Conventional Changeover | ACCL with Elmeasure M300 |
| Power Switching | Yes | Yes |
| Current Limiting | No | Yes |
| Generator Protection | Limited | Advanced |
| Load Prioritization | No | Yes |
| Demand Control | No | Yes |
| System Intelligence | Basic | High |
This comparison clearly shows why Automatic Changeover with Current Limiter (ACCL) is a smarter, safer choice.
How Elmeasure M300 Enables ACCL Logic
The strength of the Elmeasure M300 lies in its flexibility:
- Programmable setpoints
- Digital I/O for breaker or contactor control
- Real-time current evaluation
- Event-based logic execution
System integrators can configure ACCL behavior according to:
- Generator capacity
- Critical vs non-critical loads
- Site-specific operating conditions
This makes the Elmeasure M300 adaptable to a wide range of installations.
Installation and Configuration Considerations
To get the best results from ACCL:
- Current transformers must be correctly sized and installed
- Load limits should match generator ratings
- Control wiring must be fail-safe
- Testing under real load conditions is essential
When implemented correctly, ACCL becomes a silent guardian—working in the background without operator intervention.
Why This Matters for Modern Power Management
Energy systems are no longer static. With rising power costs, stricter regulations, and increasing dependence on backup power, simple switching is not enough. Intelligent control—like Automatic Changeover with Current Limiter (ACCL)—is becoming a necessity rather than an upgrade.
The Elmeasure M300 supports this transition by combining accurate metering with actionable control logic.
Conclusion
Automatic Changeover with Current Limiter (ACCL) represents the next evolution in power continuity and load management. By intelligently switching power sources while controlling current flow, ACCL protects generators, stabilizes electrical systems, and reduces operational risks.
When implemented using the Elmeasure M300, ACCL becomes a powerful tool for industries and commercial facilities looking to balance reliability, safety, and efficiency. Instead of reacting to power problems, systems equipped with ACCL anticipate and prevent them—ensuring smoother transitions, protected equipment, and optimized energy use.
In an era where power stability directly impacts productivity and safety, ACCL with Elmeasure M300 delivers control where it matters most.
At BSPL (Balaji Switchgears Pvt. Ltd.), we help customers select and implement the right Elmeasure solutions based on their load profile and operational needs. Our team provides genuine products, technical guidance, and end-to-end support to ensure seamless integration of ACCL functionality into your power system.
Looking to upgrade your facility with Elmeasure M300 and ACCL?